Description
G2R Din Rail 2P 4P ATS Dual Power Automatic Transfer Switch Electrical Selector Switches Uninterrupted Power 25A 40 63A 110V/220V BEST ATS QUALITY IN ALIEXPRESS---SILVER CONTACT POINT & RED COPPER PARTS & STABLE RELAY CONTROL City Power ⇆ Generator G2R ATS Usage Precautions: 1. 220V ATS should not be used with a voltage lower than 185V, otherwise the coil may burn out. 2. 110V ATS should not be used with a voltage lower than 90V, otherwise the coil may burn out. 3. The switch cannot be manually switched when in automatic mode, otherwise the coil may burn out. 3. 4P ATS ensure correct connection of phase sequence,otherwise the contacts may burn out. General GEYA G2R-63 automatic transfer switch is a PC class infrequent change-over switch, with two-station design (commonly used for A and standby for B), suitable for AC systems with AC 50-60hz and rated current 6A-63A. The main function of the automatic transfer switch is when the main power (common power supply A) fails, the ATS will automatically switch to the backup power (Backup power supply B) to continue working (switching speed <50 milliseconds), which can effectively solve the troubles caused by power outages. When both A and B have electricity, priority is using A Power NOTE: 1. Manual/automatic operation can ensure the opening and closing performance of electrical operation, but in manual operation , there is no guarantee due to the different _opening/closing speeds of the operators. In manual operation, there's possible for excessive silver alloy loss . Therefore, the selector switch should only be pulled to the manual position after all power has been cut off for inspection and maintenance of the operating system and contact information. 2, Normally, pull the selector switch to the electric position. When manual operation is required, pull the selector switch to the manual position. After manual operation is complete, pull the selector switch from the manual position to the automatic position. The control circuit TSE is immediately energized. After the change over is completed, the internal switch will damage the coil in the control circuit, and the coil can work normally at 85%-110% of the rated operating voltage. Too low input voltage may cause the coil to overheat and burn out. Attention! When manual operation the mode selection switch must be in "manual" position
This flashlight is even better than I'd hoped it would be. There was damage to the box but the light works well. Shipping time was good. No communication with the seller but he kept me up to date. Price was excellent, given the quality of the light. A little more attention to packing is the only suggestion I have.
Easy Breezy Transaction. Thank YOU!!! ★ª ˜¨★ª ˜˜ª.*.★☆★ Ebay seller. Ordered in 2025 after the freaking Tariff saga, thus there's an uncertainty in delivery. However, seller sent a message and refunded just in case!! Thank You!!
Original order was lost is the States. Supplier asked if I would like a refund or try again. Second shipment went out next day and arrived timely. ASAAA+++++
Related products
module converter industrial grade with isolation FT232RL USB to RS232/RS485/TTL
$ 33.631PCS NEW FOR Bussmann Fuse 170M6920
$ 484.842Pcs New R1046240 fuse 400A 1000V
$ 484.713PCS New For Ferraz Shawmut A065UD30TTI630 A302703 650V 630A Fuse
$ 464.64